

Thank you for registering for the ISS2026 Industrial Exhibition.
All exhibition booths will be located in the Exchange Gallery on the 1st Floor of Toyama International Conference Center.
Complimentary coffee and local specialty sweets will be served in the exhibition area at the following times:
December 1: 10:00 AM and 3:00 PM
December 2: 10:00 AM and 3:00 PM
December 3: 10:00 AM
A total of 10 companies will participate in the Industrial Exhibition.
Booth No.: Exhibitor
1: Toshima Manufacturing Co., Ltd.
2: SuperMag Technology (Shanghai) Co., Ltd.
3: Faraday Factory Japan LLC
4: AISupercoN
5: Fujikura Ltd.
6: Shanghai Superconductor Technology Co., Ltd.
7: K&R Creation Co., Ltd.
8: Furukawa Electric Co., Ltd.
9: IMURA JAPAN Co., Ltd.
10: Eastern Superconducting Technology (Suzhou) Co., Ltd.
We encourage all symposium participants to visit the exhibition area and learn about the latest products, technologies, and services presented by our exhibitors. We appreciate the support and contributions of all participating companies and wish them a successful exhibition at ISS2026.
On-site Exhibition
An exhibition booth will be approximately 3.6 m wide, 1.8 m deep, and 2.1 m high.
Two chairs and a 1.8 m-wide long table will be provided. A 100V 15A power supply and a white tablecloth will also be available. In addition, the exhibitor’s company name will be displayed as a booth sign.

Packages can be accepted from the afternoon of November 30, 2026. Please clearly label each package with the delivery date, venue name, exhibitor name, and booth number.
Exhibitors are kindly requested to set up their exhibition booths between 15:00 and 17:00 on November 30. Booth construction and installation work will be carried out by the venue contractor from approximately 13:00 to 15:00. Exhibitor move-in and booth preparation may commence once the construction work has been completed. Thank you for your cooperation.

Instructions details for Exhibitors
Check-in
Please check in at the 1st Floor Administration Office before using the exhibition venue. Access to the venue before the reserved time is not permitted.
Use of Common Areas
Loading areas and passageways are shared spaces. Please do not leave empty boxes, carts, trolleys, or any other items unattended in these areas. Empty cartons, crates, and cases used for exhibits must either be removed from the venue or stored in a separately rented meeting room to be used as a stockroom.
Receipt and Shipment of Goods
As a rule, the venue does not accept deliveries arriving prior to the event. Please arrange shipments so that a representative of your company can receive them directly during your contracted exhibition period. All packages must be clearly labeled with the Designated Shipping Label. If direct receipt is unavoidable, please contact the venue in advance for consultation.
For outgoing shipments, only cash-on-delivery Yamato Transport services scheduled for dispatch on the following day or later can be handled by the venue. Exhibitors are responsible for arranging all other shipping services, including: Other courier companies, Prepaid shipments, Insured shipments, Same-day dispatch, Deliveries with a specified arrival date.
Loading and Unloading Vehicles
Vehicles may stop in the south-side parking area only while loading or unloading materials. (Maximum vehicle weight: 5 tons gross vehicle weight.) Before beginning work, obtain a parking permit from the 1st Floor Administration Office and display it prominently on the dashboard. While parked, vehicle engines must be switched off. After loading or unloading is completed, long-term parking is not permitted. Please return the permit and move the vehicle promptly. Loading and unloading through the following locations is prohibited: Main entrance on the 1st floor, East-side entrance on the 1st floor, Underground paid parking area. The organizer(ISS) is responsible for ensuring safe vehicle movements and must take appropriate measures to avoid inconvenience to neighboring facilities and the public, including noise, headlights, and traffic obstruction.
Freight Elevators
For loading and unloading, please use the designated loading entrance and either the freight elevator or the emergency elevator. Passenger elevators must not be used for transporting exhibition materials.
Loading Entrance Shutter
Width: 3,600 mmHeight: 2,950 mm
Freight Elevator (Inside Dimensions)
Width: 2,200 mmHeight: 2,300 mmDepth: 2,800 mmMaximum load: 2,000 kg The doorway dimensions are the same as the internal dimensions.
Emergency Elevator (Inside Dimensions)
Width: 1,800 mmHeight: 2,650 mmDepth: 1,500 mmMaximum load: 1,150 kg
Emergency Elevator Door Opening
Width: 1,000 mmHeight: 2,100 mm
Protection of Floors and Walls
When transporting materials for installation and dismantling, please make every effort to minimize noise and avoid damaging floors, walls, or other facility surfaces. Protective covering is required when moving carts, heavy equipment, or exhibits. Please prepare suitable protective materials such as: Plywood sheets, Carpets, Other floor protection materials.
Floor Load Restrictions
Please note that floor load limitations apply to the installation and movement of exhibits. If your exhibit includes heavy equipment or machinery, please contact the venue in advance regarding Maximum allowable floor loads.
Exhibitors